F100N-ES flame arrestor, safety device in accordance with DIN EN ISO 5175-1, made of stainless steel, for hydrogen up to 17 bar
WITT safety devices for reliable protection against dangerous flashbacks in accordance with DIN EN ISO 5175-1 for hydrogen up to 17 bar. Every safety device is 100% tested. Highlights: extinguish dangerous backfires – using FA flame arresters made from sintered chrome-nickel steelextinguish backfires – using temperature-controlled after-flow barriers (TV) Application: the safety devices protect against flame flash-back in gas supply systems For maximum operating pressures up to 17 bar; for hydrogen, e.g. in flame spraying applications when using corrosive gases in the chemical industry, in laboratories or in process engineering Installation can be carried out in any orientation Gas types: Hydrogen (others on request) The ambient temperature must not exceed 60 °C Special versions are not available in the shop, but can be supplied on request. If you have any specific requirements or special requests, please contact us – we’ll be happy to help!
F53N-ES flame arrestor, universal safety device in accordance with DIN EN ISO 5175-1, made of stainless steel, without a non-return valve
WITT safety devices for reliable protection against dangerous gas backflow and flame-back – in accordance with DIN EN ISO 5175-1. Every safety device is 100% tested. The world’s best safety devices – highlights: extinguish dangerous backfires – using FA flame arresters made from sintered chrome-nickel steelextinguish backfires – using temperature-controlled backflow preventers (TV) prevent the formation of explosive mixtures in the gas supply – using gas non-return valves (NV) Application: The safety devices protect against flame flash-back in gas supply systems when corrosive gases are used in the chemical industry, in laboratories or in process engineering Installation can be carried out in any orientation Gas types: acetylene, natural gas, liquefied petroleum gas, hydrogen, oxygen, compressed air (others on request) The ambient temperature must not exceed 60 °C Special versions are not available in the shop, but can be supplied on request. If you have any specific requirements or special requests, please contact us – we’ll be happy to help!
F53N/H-ES flame arrestor, high-pressure safety device in accordance with EN ISO 5175-1, made of stainless steel, without non-return valve
WITT safety devices for reliable protection against dangerous gas backflow and flame-back – in accordance with DIN EN ISO 5175-1. Every safety device is 100% tested. The world’s best safety devices.Highlights: extinguish dangerous backfires – using FA flame arresters made from sintered chrome-nickel steelextinguish backfires – using temperature-controlled backflow preventers (TV) prevent the formation of explosive mixtures in the gas supply – using gas non-return valves (NV) ensure a long service life by protecting against contaminants from the gas supply – via filters in the gas inlet Gas types: natural gas, liquefied petroleum gas, hydrogen, ethylene (others on request) Application: the safety devices protect against flame flashback in gas supply systems when corrosive gases are used in the chemical industry, in laboratories or in process engineering Installation can be carried out in any orientationThe ambient temperature must not exceed 70°CWithout a non-return valve for minimal operating overpressures upstream and downstream of analytical instruments Special versions are not available in the shop, but can be supplied on request. If you have any specific requirements or special requests, please contact us – we’ll be happy to help!
F85-10N-ES flame arrestor, stainless steel safety device in accordance with DIN EN ISO 5175-1 without a non-return valve for minimal operating overpressures
WITT safety devices for reliable protection against dangerous gas backflow and flame-backflow in accordance with DIN EN ISO 5175-1. Every safety device is 100% tested. The world’s best safety devices. Highlights: extinguish dangerous backfires – using FA flame arresters made from sintered chrome-nickel steelextinguish backfires – using temperature-controlled backflow preventers (TV) prevent the formation of explosive mixtures in the gas supply – using gas non-return valves (NV) Application: The safety devices protect against flame flash-back in gas supply systems without a non-return valve for minimal operating overpressures upstream and downstream of analytical instruments for use with corrosive gases in the chemical industry, in laboratories or in process engineering Installation can be carried out in any orientation Gas types: natural gas, liquefied petroleum gas, hydrogen, oxygen, compressed air, ethylene (others on request) The ambient temperature must not exceed 60 °C Special versions are not available in the shop but can be supplied on request. If you have any specific requirements or special requests, please contact us – we’ll be happy to help!
Flame arrestor F85-10N/H-ES, stainless steel safety device in accordance with DIN EN ISO 5175-1 without non-return valve, up to 10 bar
WITT safety devices for reliable protection against dangerous gas backflow and flame-back – in accordance with DIN EN ISO 5175-1. Every safety device is 100% tested. The world’s best safety devices.Highlights: extinguish dangerous backfires – using FA flame arresters made from sintered chrome-nickel steelextinguish backfires – using temperature-controlled backflow preventers (TV) prevent the formation of explosive mixtures in the gas supply – using gas non-return valves (NV) Application: The safety devices protect against flame flash-back in gas supply systems when corrosive gases are used in the chemical industry, in laboratories or in process engineering Installation can be carried out in any orientation Gas types: natural gas, liquefied petroleum gas, hydrogen, ethylene (others on request) The ambient temperature must not exceed 60 °C Special versions are not available in the shop but can be supplied on request. If you have any specific requirements or special requests, please contact us – we’ll be happy to help!
RF53N-ES flame arrestor, universal safety device in accordance with DIN EN ISO 5175-1, made of stainless steel
WITT safety devices for reliable protection against dangerous gas backflow and flame-back – in accordance with DIN EN ISO 5175-1. Every safety device is 100% tested. The world’s best safety devicesHighlights: extinguish dangerous backfires – using FA flame arresters made from sintered chrome-nickel steelextinguish backfires – using temperature-controlled backflow preventers (TV) prevent the formation of explosive mixtures in the gas supply – using gas non-return valves (NV) ensure a long service life by protecting against contaminants from the gas supply – via filters in the gas inlet Gas types: acetylene, natural gas, liquefied petroleum gas, hydrogen, oxygen, compressed air (others on request) Application: the safety devices protect against gas backflow (RF53N-ES) and flame flashback in gas supply systems when corrosive gases are used in the chemical industry, in laboratories or in process engineering Installation can be carried out in any orientation The ambient temperature must not exceed 60 °C Special versions are not available in the shop, but can be supplied on request. If you have any specific requirements or special requests, please contact us – we’ll be happy to help!
RF53N/H-ES flame arrestor, universal safety device in accordance with DIN EN ISO 5175-1, made of stainless steel
WITT safety devices for reliable protection against dangerous gas backflow and flame-backflow in accordance with DIN EN ISO 5175-1. Every safety device is 100% tested. The world’s best safety devices.Highlights: extinguish dangerous backfires – using FA flame arresters made from sintered chrome-nickel steelextinguish backfires – using temperature-controlled backflow preventers (TV) prevent the formation of explosive mixtures in the gas supply – using gas non-return valves (NV) Application: The safety devices protect against flame flash-back in gas supply systems without a non-return valve for minimal operating overpressures upstream and downstream of analytical instruments for use with corrosive gases in the chemical industry, in laboratories or in process engineering Installation can be carried out in any orientation Gas types: natural gas, liquefied petroleum gas, hydrogen, ethylene (others on request) The ambient temperature must not exceed 60 °C Special versions are not available in the shop, but can be supplied on request. If you have any specific requirements or special requests, please contact us – we’ll be happy to help!
RF85-10N-ES flame arrestor, stainless steel safety device in accordance with DIN EN ISO 5175-1 for increased flow rates
WITT safety devices for reliable protection against dangerous gas backflow and flame-backflow in accordance with DIN EN ISO 5175-1. Every safety device is 100% tested. The world’s best safety devices.Highlights: extinguish dangerous backfires – using FA flame arresters made from sintered chrome-nickel steelextinguish backfires – using temperature-controlled backflow preventers (TV) prevent the formation of explosive mixtures in the gas supply – using gas non-return valves (NV)ensure a long service life by protecting against contaminants from the gas supply – via filters in the gas inlet Application: The safety devices protect against flame flash-back in gas supply systems when corrosive gases are used in the chemical industry, in laboratories or in process engineering Installation can be carried out in any orientation Gas types: acetylene, natural gas, liquefied petroleum gas, hydrogen, oxygen, compressed air, ethylene (others on request) The ambient temperature must not exceed 60 °C Special versions are not available in the shop but can be supplied on request. If you have any specific requirements or special requests, please contact us – we’ll be happy to help!